Difference between revisions of "PH Meter"

From Milk The Funk Wiki
Jump to: navigation, search
(added Dustin Carver's input on MW102 features)
Line 23: Line 23:
 
* Automatic buffer recognition <ref name="ajdelange"></ref>.
 
* Automatic buffer recognition <ref name="ajdelange"></ref>.
 
''Disadvantages'':
 
''Disadvantages'':
* Despite having an automatic calibration message, this pH still often needs to be calibrated before each use <ref name="ajdelange"></ref>.
+
* Despite having an automatic calibration message, this pH still often needs to be calibrated before each brew day <ref name="ajdelange"></ref>.
  
 
====[http://www.milwaukeetesters.com/MW102.html Milwaukee MW102 pH/Temp Meter (formerly SM101 and MW101)].====
 
====[http://www.milwaukeetesters.com/MW102.html Milwaukee MW102 pH/Temp Meter (formerly SM101 and MW101)].====

Revision as of 00:16, 19 April 2015

A pH Meter is not only considered by some to be an essential tool for all grain homebrewing and commercial brewing, but is also a very useful tool to have for making sour beer.

Recommend pH Meters

High End pH Meters

(To do)

Budget pH Meters

pH meters can range from $30 to $500+. The problem with many of the cheaper pH meters is that their reliability and longevity are often questionable [1]. Commonly, two pH meters are recommended by trustworthy sources (AJ Delange and Kai Troester).

Hach Pocket Pro+ pH Tester with Replaceable Sensor.

Hach Pocket Pro+

Features:

  • This pH meter is recommended by AJ Delange [1][2].
  • Does not require storage solution (there is an o-ring seal on the cap, which only needs to have a few drops of distilled water in it).
  • Replaceable sensor.
  • Stability [1].
  • 2 Buffer calibration.
  • Electrode longevity [1].
  • Junction resistant to fouling by sugars, proteins [1].
  • Lets the user decide when to accept a buffer calibration reading [1].
  • ATC [1].
  • Automatic buffer recognition [1].

Disadvantages:

  • Despite having an automatic calibration message, this pH still often needs to be calibrated before each brew day [1].

Milwaukee MW102 pH/Temp Meter (formerly SM101 and MW101).

Milwaukee MW102

Features:

  • This pH meter is recommended by Kai Troester (SM101 originally) [3].
  • 2 Buffer calibration.
  • ATC.
  • Stability [4].
  • Separate pH and temperature probes (can use as RTD for temp monitoring) [5].
  • Storage solution container screws into probe [5].

Disadvantages:

Buffer Solution