Titratable Acidity

From Milk The Funk Wiki
Revision as of 15:04, 1 December 2017 by DanABA (talk | contribs) (added buret size option)
Jump to: navigation, search

Titratable Acidity (abbreviated as TA) is an approximation of the Total Acidity of a solution, and has long been used in the production of wine. It is usually expressed in units of grams per liter (g/L), although other formats are also used [1]. Titratable Acidity is often mistakenly confused with Total Acidity, but they are not the same thing [2]. While Total Acidity is a more accurate measurement of the total acid content of a solution, Titratable Acidity is used because it is easier to measure. Although titratable acidity does not measure all acids, TA is generally considered a better way to measure perceivable acidity in sour beer and cider than pH [3][4].

TA versus pH

Many sour beer producers use pH to help determine how "sour" their beer is in relation to a set goal, previous batches, or commercial examples. However, often times TA is a more accurate measurement of how acidic a beer will be perceived on the palate.

pH

In chemistry, pH is the negative log of the activity of the free (dissociated) hydrogen ion (H+) in an aqueous solution. Solutions with a pH less than 7 are said to be acidic and solutions with a pH greater than 7 are basic or alkaline. Pure water has a pH of 7.

The pH scale is traceable to a set of standard solutions whose pH is established by international agreement [5]. Primary pH standard values are determined using a concentration cell with transference, by measuring the potential difference between a hydrogen electrode and a standard electrode such as the silver chloride electrode. Measurement of pH for aqueous solutions can be done with a glass electrode and a pH meter, or using indicators.

pH measurements are important in medicine, biology, chemistry, agriculture, forestry, food science, environmental science, oceanography, civil engineering, chemical engineering, nutrition, water treatment & water purification, and many other applications [5].

pH is best tested in sour beers using a pH Meter and is most useful for biological parameters. Microbial growth, vitality, and death are evaluated based on pH rather than TA. This means pH should be used when testing sanitizer, Wort Souring, starter cultures, etc.

TA

Titration is an attempt to quantify an unknown substance with a known one. Titratable acidity asks how much of a given base (in our case sodium hydroxide, NaOH) neutralizes the acid(s) (lactic, phosphoric, etc.) in a volume of liquid, thus estimating both free hydrogen ions and hydrogen ions that are bound to weak acids taht can react with the strong base and be neutralized [6]. The units of TA can be quoted in g/L, or in other words, so many grams (of a specific acid) in so much substrate (beer) brings the pH of that substrate to a predetermined pH (for instance, a pH of 7 or 8.2).

Titratable acidity does not target a specific acid in the liquid you are measuring. Beer is composed of lactic acid, but also phosphoric acid, acetic acid, etc. While the latter are in minute quantities, they still affect the end result. For our purposes (and convention), we assume 100% lactic acid in the sample for our titration.

Why care about titratable acidity? pH quantifies the number of free hydrogen ions (or hydrogen ion equivalents) in liquid. Your palate does not measure pH directly. Your palate interprets a multi-variable substrate called beer, which also contains "weak acids" such as lactic acid that contain bonded hydrogen ions that are not measured by pH. Titratable acidity attempts to put another quantifiable handle on your beer akin to pH; the measurement better captures how “acidic” the beer may taste to you. Again, there are other acids than lactic in the beer, leading to differences in flavor between beers of the same TA. As a general rule of thumb, the lower the pH, the higher the TA, however, TA and pH are not directly correlated. TA has been proposed as a more accurate representation of perceived acidity because we taste both free hydrogen ions and those that are bound to organic acids [7][8]. There is some disagreement on whether TA is a more accurate measurement of perceived acidity than pH; see Limitations of TA for details.

Titratable acidity can be expressed in terms of different acids. In wine, TA is generally expressed in terms of tartaric acid (molecular weight of 150.09). In sour beer, TA is expressed in terms of lactic acid (molecular weight 90.08). To express TA in terms of a specific acid, the molecular weight of the specified acid is used in the TA calculation. In the example below, we express the TA value in terms of lactic acid. See appendix 1 in this paper on how to convert the titratable acidity value for different acids. Note that this is NOT a measurement of how much lactic acid or tartaric acid there is, it is an expression of measurement like how feet and meters are two different expressions of measurement for the same thing (distance). For example, a TA of 3.0 measured in units of tartaric acid is equal to a TA 3.6009 measured in units of lactic acid. Therefore, an argument can be made that TA measurements should always be specified as to which acid was used in the calculation.

The ASBC[9] equation for TA in units of lactic acid (the 0.9 constant represents TA expressed in units of lactic acid) is as follows:

Example

"I agree that maths are hard." - Lance Shaner.

What you will need:

  • Sample of beer to be measured. Must be fully degassed if it has any carbonation (pour through a coffee filter, or shake and ventilate to decarbonate).
  • Sodium Hydroxide, NaOH. Available in liquid or powder form. Be sure to note its molarity (M), units of mol/L. For more info on mol, see here.
Safety caution: always wear safety glasses and gloves when handling NaOH in any concentration. NaOH can cause severe burns. In concentrations higher than 0.1, NaOH can corrode through clothing. See Canadian Centre for Occupational Health and Safety on Sodium Hydroxide.
  • Nitrile or latex gloves. NaOH is a strong base, it will hurt you if you get any on your skin.
  • Pipettes and glassware, with precision down to 0.1 mL (25 or 50mL buret [10]). Alternatively, you can use a precision scale to dose the base into the beer, if you know the density of both liquids (preferred method).

We need a precise volume of the beer and the specific gravity of the beer. If the specific gravity cannot be measured easily for some reason, then estimating it will be fine for this equation since small differences in specific gravity don't greatly impact the results of the equation. In this example, we have 15 mL with a specific gravity of 1.015. We also need NaOH in liquid form. Typically, it is sold in 0.1M form. Now, the trickiest part of this is adding precise amounts of NaOH (say, 0.1-0.5 mL at time), to your 15 mL of beer. Every time you add NaOH, you must vigorously stir the sample so it is well-mixed. Then you can measure its pH. You continue this until you reach the desired pH baseline of 8.2.

Note: The baseline value of 8.2 pH is somewhat arbitrary, but it is the US (ASBC[9]) and Australian industry standard. A pH of 7 is a neutral pH and the pH of water, whereas ~8.2 is near the equivalence point for a lactic acid/sodium hydroxide reaction. A pH of 8.2 is also where a titration dye, phenolphthalein, changes color. A well-calibrated pH meter is easier to use than dye, not to mention its superior accuracy and precision, if used correctly (well-calibrated, probe well-maintained, etc.). A pH of 7 is the European industry standard for measuring TA in wine [11]. See also this MTF thread.

At or around a pH of 8.2, we have reached our equivalence point for a titration of pure NaOH and pure lactic acid. We need to convert the moles of NaOH we added into moles of lactic acid, and then divide the equivalent grams of lactic acid by the original volume of beer. That gets us g/L, and our titratable acidity. For a numerical example, assume 15mL beer with a gravity of 1.015, 5mL 0.1M NaOH:

The Eccentric Beekeeper TA Spreadsheet calculates TA as well as blends of beers with different TA values. It also includes a correction for beer final gravity. The idea is that the more residual sugar there is the less effect the acid will have on your perception. This is likely not that straightforward since you can have varying levels of sweetness at the same given FG [12].

In summary, the measurement of titratable acidity is a technique to quantify the total acid level of a beer. A major assumption was made: all the acid in the liquid was lactic acid. Two beers could have the same TA measurement, but have differing levels of palatable acidity, due to the acid makeup of the beer.

ASBC Modification Using Mass

Here MTF member Andy Carter presents an alternative calculation for measuring titratable acidity. The ASBC method requires both an accurate measurement of both beer volume and density. Depending on the quality of lab equipment available, these measurements can have variable error bars. In general, more accurate mass scales are more affordable than similarly accurate volume or density instruments; therefore, only using the beer and acid mass will lead to a more consistent measurement. Additionally, small gravity differences don't have a large impact when using the ASBC calculation. The following calculation for TA does not use specific gravity.

For a numerical example of this alternative calculation for TA, assume 15mL beer, 5mL 0.1M NaOH:

Videos

Titration of a weak acid with a strong base by Kahn Acadmey part 1:

Part 2:

Measuring Titratable Acidity in Wine (use the calculation above instead of the calculation in the video to express the value in terms of lactic acid):

Limitations of TA

Although a better representation of perceived acidity than pH, titratable acidity might have some limitations on accurately measuring perceived acidity in beer. See this MTF discussion for details.

See Also

Authorship

Originally written by James Howat with major updates by Andy Carter, and with input from Dan Pixley and organic chemist Mike Castagno.

References