====Cleaning and Sanitizing====
The goal of cleaning is to remove as much biomaterial as possible, while the goal of sanitizing is to reduce the population of viable microbes as much as possible and prevent them from growing on surfaces during the non-production time. It's been shown that chemical cleaners are better at removing biofilms than sanitizers and disinfectants, and sanitizers that kill cells in suspension may not be effective at killing cells within biofilms. Complete removal of unwanted microbes within biofilms can be achieved by first using a cleaning agent to remove the biomass followed by a sanitizing /disinfecting agent. CIP procedures may not be enough to remove biofilms without high turbulent flow with spray nozzles and the use of heat (low cleaning temperatures are not effective at removing biofilms). Chlorinated alkaline detergents were found to be the most effective at removing biofilms <ref name="Wirtanen_2001" />. Below is a typical CIP process according to [http://www.vtt.fi/inf/pdf/publications/2000/P410.pdf Erna Storgårds (2000)]; CIP processes at room temperatures are not adequate enough to remove biofilms, so use hot temperatures when applicable. Use the highest chemical concentrations recommended by the vendor. Also, the higher the velocity of the cleaning fluid through the system, the more efficient it is at removing biofilms:
{| class="wikitable sortable"